Everything You Need To Know About Cat6 Riser Bare Copper Cable

One of the most popular Ethernet cables is the Cat6 Riser Bare Copper Cable. Both household and business uses have made extensive use of the cable. You need not be concerned if you lack sufficient knowledge about this communication miracle because we are here to assist you. So, let's get this party started!

Jacket

The CMR-rated jacket on the Cat6 Riser Copper cable is the second-best jacket rating among ethernet cables. The initials CMR stand for Communications Multipurpose, and jackets with these marks are fire-resistant. It means that when these cables come into touch with fire, they generate extremely poisonous materials and gases while also halting the spread of the fire. These coats are also resistant to UV and sunshine. Because the jackets are thick and composed of high-quality polyvinyl chloride, they provide excellent crosstalk and electromagnetic interference protection. It means that the signal quality and data integrity are preserved and not compromised.

Bandwidth & Data Transfer Rates

The Cat6 Riser Cable offers 10 Gbps (gigabits per second) data transfer rates over a distance of 100 meters (328 ft). The cable has a maximum bandwidth of 750 MHz. The cable's larger bandwidth capacity allows it to maintain signal quality over long distances.

Uses

Cat6 Riser Pure Copper is intended for usage in the riser or vertical areas of structures, such as between floors and walls. Because the chance of a fire erupting in these regions is higher, you can only use a riser-rated CMR cable. This cable can also be utilized for exterior installations.

Conductors

The interior structure is comprised of eight pure copper conductors. These eight conductors are twisted together to form four twisted pairs. Because these are pure copper conductors, they work admirably even under extreme situations (environments where crosstalk and EMI are present to a greater extent). CCA (copper-clad aluminum) conductors have less attenuation than pure copper conductors. It means that the signal strength is maintained and you have continuous access to the internet.

Types

There are two variations of the Cat6 Riser Copper: shielded and unshielded.

The shielded version adds an additional layer or levels of protection in the form of a conductive material shield. This shield wraps over the inner eight conductors, providing additional crosstalk and EMI protection. Shielded cables are also available in a variety of configurations. These cables are utilized in extreme conditions.

The term "unshielded cable" refers to a cable that is protected only by its outer jacket. In usual situations, these wires are chosen. Shielded cables are more expensive than unshielded cables in terms of pricing.

Standards

The Cat6 Riser Pure Copper cable complies with FCC, CE, CSA, ISO/IES, and RoHS regulations. The cable has also been tested with a Fluke DXT-1800 Versiv Cable Analyzer to guarantee that it is totally safe to install. It is 23AWG (American Wire Gauge) and comes in an easy-pull-box packaging because it is a bulk cable. 10BASE-T, 100BASE-TX Fast Ethernet, 1000BASE-T (IEEE802.3), 100VG-AnyLAN (IEEE802.12), 650 MHz Broadband Video Voice, T1, ISDN 155/ 622 Mbps, and ATM PoE are all supported by the riser cat6 1000ft bulk cable blue (Power over Ethernet).